F2
Protherm Floor Sensor Open Circuit

F2 displayed and thermostat cannot read floor temperature in underfloor heating mode.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Disconnected floor sensor cable, Broken NTC floor sensor, Loose terminal screws on sensor input, Damaged cable in floor conduit

How to Fix / Troubleshooting

Safety: Turn off power to the thermostat and boiler before working on wiring. Use a non-contact voltage tester to confirm power is off.

  • Step 1 – Check sensor wiring at thermostat:
    • Remove the thermostat from the wall plate.
    • Locate the Floor Sensor terminals (often marked S1/S2 or similar).
    • Ensure both sensor wires are firmly clamped and not broken.
    • Tighten terminal screws gently.
  • Step 2 – Measure sensor resistance:
    • Disconnect the two floor sensor wires from the thermostat.
    • Use a multimeter set to kΩ range.
    • Measure resistance across the two sensor wires.
    • A typical Protherm NTC floor sensor (10k at 25°C) should read between 5–20 kΩ depending on floor temperature.
    • If the meter shows OL (open circuit), the sensor or cable is broken.
  • Step 3 – Inspect cable route:
    • If accessible, check junction boxes or conduit where the sensor cable runs.
    • Look for crushed, cut, or pinched cable sections.
  • Step 4 – Replace floor sensor:
    • If the sensor is open circuit, install a new Protherm NTC floor sensor in the existing conduit.
    • Pull out the old sensor carefully using the cable as a draw wire.
    • Feed the new sensor cable through the conduit to the thermostat.
    • Connect to the sensor terminals and secure.
  • Step 5 – Reconfigure thermostat:
    • In the installer menu, ensure Floor sensor is enabled and the correct sensor type is selected.
    • Restore power and confirm F2 is cleared and floor temperature is displayed.