Possible Causes
Failed defrost control board in outdoor unit, Communication error between thermostat and defrost board, Sensor fault on outdoor coil temperature sensor, Miswired defrost sensor harness
How to Fix / Troubleshooting
Safety first: Turn off power to the outdoor unit at the disconnect before opening panels.
Steps:
- Inspect defrost board: Locate the Rheem defrost control board in the outdoor unit. Check for status LEDs and compare blink codes to the service label.
- Check coil sensor: Verify the outdoor coil temperature sensor is properly clipped to the coil and its wiring harness is intact and fully seated on the board.
- Look for corrosion: Inspect connectors and the board for corrosion or insect damage.
- Reset power: Turn power off for several minutes, then restore and observe if E16 clears.
- If E16 persists and board shows error: The defrost board or coil sensor may need replacement. This should be performed by a qualified technician.