E6
Ruud
Outdoor Temperature Sensor Fault
Thermostat shows E6 and outdoor temperature reading is missing or incorrect; heat pump balance or lockout may not work
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted outdoor temperature sensor connected to Ruud outdoor unit, Broken sensor wiring, Incorrect sensor type installed, Failed sensor input on outdoor control board
How to Fix / Troubleshooting
Safety: Turn OFF power to the outdoor unit at the disconnect and breaker before opening panels.
- Locate sensor: Find the Ruud outdoor temperature sensor, typically mounted near the outdoor unit coil or in the control compartment, connected to the outdoor control board.
- Inspect wiring: Check the sensor leads for cuts, UV damage, or loose connections at the control board terminals. Tighten terminals and repair or replace damaged wire.
- Resistance test: With power OFF, disconnect the sensor and measure its resistance with a multimeter. Compare the reading to the Ruud temperature/resistance chart for the ambient temperature. If the reading is far off, replace the sensor.
- Board input check: If a known-good sensor still reads incorrectly at the thermostat, the outdoor board's sensor input may be faulty and require board replacement by a technician.
- Reconfigure thermostat: After sensor replacement, reboot the system and verify that the thermostat now shows a reasonable outdoor temperature and E6 is cleared.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Ruud Outdoor Temperature Sensor