Saunier Duval
Short Cycling Due to Control Settings
Thermostat shows frequent short heating cycles (boiler starts and stops every few minutes)
Advertisements
Possible Causes
Hysteresis set too low, TPI cycle time too short, Oversized boiler relative to system, Thermostat installed in small or rapidly heated room
How to Fix / Troubleshooting
Safety: No mains work required for thermostat settings; boiler adjustments should be done by a professional.
- Adjust control parameters: In the installer menu, increase the cycle time and/or hysteresis to reduce the number of starts per hour.
- Relocate thermostat: Move the thermostat to a larger, representative room if currently in a small hallway or near a radiator.
- Lower flow temperature: Reduce boiler flow temperature to lengthen run times and reduce cycling.
Persistent short cycling may require a heating engineer to balance the system or adjust boiler parameters.
Advertisements
Repair Difficulty
Easy
2/5
Advertisements