E13
Schneider Electric Real-Time Clock / Backup Memory Fault

E13 displayed and thermostat indicates date/time or schedule memory error; schedules may be lost after power cycles.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed RTC chip on PCB, Depleted backup battery or supercapacitor, Corrupted schedule data, Power interruptions beyond design limits

How to Fix / Troubleshooting

Safety: No mains wiring changes are needed.

Steps:

  • Manually set the correct date and time in the thermostat menu and reprogram a simple schedule.
  • Turn off power to the thermostat for a few minutes, then restore power and check if the time and schedule were retained.
  • If the thermostat loses time/schedule and shows E13 again, the internal RTC or backup storage is failing.
  • Some models include a replaceable coin-cell battery; if accessible and documented by Schneider Electric, replace it with the specified type, observing polarity.
  • If there is no user-replaceable battery or replacement does not resolve the issue, the thermostat must be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Real-Time Clock / Backup Battery
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements