E20
Schneider Electric
Sensor Calibration Out of Range
Thermostat shows E20 and indicates calibration error; temperature readings are clearly wrong.
Advertisements
Possible Causes
Incorrect manual offset applied, Internal ADC (analog-to-digital converter) fault, Sensor drift beyond calibration range, Firmware bug affecting calibration table
How to Fix / Troubleshooting
Safety: No high-voltage work is needed.
Steps:
- Compare the thermostat temperature reading with a reliable reference thermometer placed nearby.
- Enter the thermostat settings and check the temperature offset or calibration menu. Reset the offset to 0 or factory default.
- If the reading is still off by more than a few degrees, perform any built-in calibration procedure described in the Schneider Electric manual.
- Update the thermostat firmware to the latest version via app or gateway, as some calibration issues are firmware-related.
- If the error persists and readings are far off, the internal sensor or ADC circuitry is defective; replace the thermostat.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Internal Temperature Sensor / ADC Circuit
Check Price on Amazon