Excessive Auxiliary Heat Usage
Thermostat displays "Aux Heat" frequently on a heat pump system
Advertisements
Possible Causes
Aux heat balance point set too high in Sensi settings, Outdoor temperature sensor misreading (if used), Heat pump capacity insufficient or malfunctioning, Thermostat configured for wrong heat pump type
How to Fix / Troubleshooting
Safety: Configuration changes can be made without cutting power.
Steps to reduce aux heat use:
- Check configuration: In the Sensi installer menu, confirm the system is set as a heat pump with auxiliary heat and that staging logic is correct.
- Adjust balance point (if available): Lower the outdoor temperature at which auxiliary heat is allowed to engage, so the heat pump does more of the work.
- Avoid large setpoint changes: Use smaller temperature adjustments and rely on schedules instead of large manual setbacks that trigger aux heat.
- Monitor outdoor conditions: If aux heat runs even in mild weather, the heat pump may not be operating correctly and should be checked by an HVAC technician.
When to call a pro: Persistent heavy aux heat usage increases energy costs and indicates a possible heat pump performance issue that requires professional diagnosis.