E0
TP-Link Kasa
Internal Sensor Calibration Error
Thermostat displays E0 and will not control heating or cooling
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Onboard temperature sensor out of range, Corrupted configuration data, Firmware glitch, Main control PCB fault
How to Fix / Troubleshooting
Safety first: Turn off power to the thermostat at the HVAC system switch or circuit breaker before removing it from the wall.
Steps to try:
- Reboot the thermostat: Turn the HVAC breaker off for 60 seconds, then back on. Wait 3–5 minutes to see if E0 clears.
- Factory reset: From the Kasa app, open the thermostat device > Settings > Device Info > Factory Reset (wording may vary). Reconfigure Wi‑Fi and schedules and check if the error returns.
- Check for extreme conditions: Ensure the thermostat is not installed in direct sunlight, above a heat register, or on an exterior wall that is very hot or cold. These can push the internal sensor out of its calibrated range.
- Update firmware: In the Kasa app, check for a firmware update for the thermostat and install it if available.
- If E0 persists: The internal sensor or main control board is likely defective. Replacement of the thermostat assembly is typically required.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Main Control PCB / Internal Temperature Sensor Module
Check Price on Amazon
We may earn a commission from links on this page.