E4
TP-Link Kasa Compressor / Outdoor Unit Control Fault (Y Circuit Error)

E4 error appears when calling for cooling; outdoor unit does not start

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open Y (cooling call) wire, Short between Y and C or R, Failed relay on thermostat cooling output, Blown fuse on outdoor condenser control board

How to Fix / Troubleshooting

Safety: Turn off power to both indoor and outdoor units at the breakers before working on wiring.

  • Check thermostat wiring: At the thermostat backplate, verify the Y wire is firmly connected and not touching other terminals. Tighten the terminal screw.
  • Inspect at air handler/furnace: Locate the Y connection on the furnace/air handler control board. Ensure the Y wire to the outdoor unit is secure and not corroded.
  • Outdoor unit check: With power off, open the outdoor condenser’s control panel. Inspect the low-voltage connections and the small control fuse if present. Replace a blown fuse only after checking for shorts.
  • Test operation: Restore power, set the thermostat to Cool and lower the setpoint. Listen for the contactor click at the outdoor unit. If there is no click and E4 returns, the thermostat’s Y output or the outdoor control board may be faulty.
  • Resolution: If wiring and fuses are good, replace the thermostat. If problem persists, have a technician test the outdoor unit’s control board and contactor.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Cooling Call (Y) Output Circuit / Outdoor Unit Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements