E0
Trane
Communication Bus Failure
Thermostat displays E0 and will not communicate with the HVAC system or Trane Home app
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted Trane ComfortLink II communication bus wiring, Miswired R/C/Y1/Y2/G terminals, Failed thermostat communication module, Blown low-voltage fuse on Trane air handler or outdoor unit control board
How to Fix / Troubleshooting
Safety first: Turn off power to the air handler/furnace and outdoor unit at the breakers before touching any thermostat or control wiring.
- Step 1 – Reboot the thermostat: Remove the thermostat from its wall sub-base (if model allows) for 30 seconds, then reattach. On some Trane smart thermostats, use the Settings > Reboot option.
- Step 2 – Check HVAC power: Confirm the indoor unit and outdoor unit breakers are ON. Verify the service switch at the air handler/furnace is ON.
- Step 3 – Inspect low-voltage fuse: Open the blower compartment on the Trane air handler/furnace and locate the 3–5A low-voltage blade fuse on the control board. If blown, replace with the same rating only. If it blows again, stop and call a technician.
- Step 4 – Inspect thermostat wiring: With power still OFF, remove the thermostat from the wall and verify that R, C, Y1, Y2, G, W1, W2, and data/communication terminals (if ComfortLink II) are firmly seated and not shorted. Look for bare copper touching other terminals.
- Step 5 – Check communication cable: For ComfortLink II systems, inspect the 2- or 4-wire communication cable between thermostat, indoor unit, and outdoor unit. Repair any damaged insulation and tighten all terminal screws.
- Step 6 – Restore power and test: Turn power back on and wait 3–5 minutes for the thermostat to re-establish communication. If E0 persists, the thermostat communication module or a system control board may be defective and professional diagnosis is recommended.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Trane Smart Thermostat (ComfortLink II or XL series) or Trane Air Handler Control Board
Check Price on Amazon