Trane Improper Cycle Rate / Differential Settings

Thermostat frequently cycles the system on and off (short cycling)

Advertisements

Possible Causes

Cycle rate set too high in thermostat configuration, Temperature differential too narrow, Oversized Trane system, Thermostat located in drafty area

How to Fix / Troubleshooting

Note: Short cycling can reduce efficiency and wear out equipment.

  • Step 1 – Check cycle settings: In the thermostat installer or advanced settings, adjust the cycle rate or temperature differential to allow longer run times (e.g., 0.5–1.0°F differential).
  • Step 2 – Verify thermostat location: Ensure the thermostat is not in a draft, near exterior doors, or directly in the airflow of a supply vent.
  • Step 3 – Check for oversizing: If the system reaches setpoint very quickly and shuts off, the equipment may be oversized. Consult an HVAC professional for load analysis.
  • Step 4 – Observe operation: After adjustments, monitor system operation over several hours to confirm longer, more stable cycles.