Trane
Humidity Sensor Miscalibration
Thermostat shows indoor humidity far from actual room humidity
Advertisements
Possible Causes
Internal humidity sensor drift, Thermostat installed near humidifier outlet or bathroom, Condensation inside thermostat, Firmware calibration error
How to Fix / Troubleshooting
Note: Incorrect humidity readings can cause over- or under-humidification.
- Step 1 – Compare with hygrometer: Use a separate digital hygrometer placed near the thermostat to compare readings.
- Step 2 – Adjust humidity offset: If the thermostat supports humidity calibration, adjust the offset to match the reference hygrometer.
- Step 3 – Improve placement: Avoid installing the thermostat near humidifiers, kitchens, or bathrooms where humidity fluctuates rapidly.
- Step 4 – Dry out condensation: If condensation is visible, gently dry the area and improve ventilation around the thermostat.
- Step 5 – Replace thermostat if error is large and persistent: A failing humidity sensor usually requires thermostat replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Trane Smart Thermostat
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements