Lo
Tuya Temperature Below Measurement Range / Sensor Underflow

Display shows 'Lo' or very low temperature and thermostat will not heat correctly

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Sensor reading below minimum supported temperature, Faulty NTC sensor giving under-range value, Thermostat installed in unheated space (garage, attic) below spec, Loose sensor connection on Tuya PCB

How to Fix / Troubleshooting

Safety first: Turn off power if you open the thermostat.

Steps to troubleshoot:

  • Verify the thermostat is installed in a location within its rated operating temperature (commonly 0–50°C / 32–122°F).
  • Move the thermostat to a more suitable indoor location if necessary.
  • Inspect and reseat the internal sensor connector or check solder joints if accessible.
  • Measure sensor resistance and compare to the NTC chart; if it is much higher than expected for the ambient temperature, the sensor may be open or out of spec and should be replaced.
  • After repair or relocation, restore power and confirm that the reading returns to normal and 'Lo' disappears.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Internal NTC Temperature Sensor (Tuya Thermostat)
Check Price on Amazon