Vaillant
Poor Temperature Control / Overshoot
Vaillant smart thermostat shows large temperature swings, with the room alternately too hot and too cold.
Advertisements
Possible Causes
Incorrect control mode (on/off vs modulating) selected, Thermostat installed in draught or near heat source, Aggressive setback or schedule changes, Incorrect heating curve or hysteresis settings
How to Fix / Troubleshooting
Safety: No electrical work required.
- 1. Check thermostat location: Ensure it is on an interior wall, away from radiators, windows, and draughts. Relocate if necessary.
- 2. Review control settings: In the Vaillant controller menu, select the recommended control mode for your boiler (eBUS modulating where supported) and adjust hysteresis or cycle rate if available.
- 3. Smooth schedules: Avoid large, sudden setpoint changes. Use smaller setbacks and gradual transitions.
- 4. Adjust heating curve: For weather‑compensated systems, slightly lower the heating curve to reduce overshoot.
- 5. Monitor performance: Make one change at a time and observe for 24–48 hours before further adjustments.
Advertisements
Repair Difficulty
Very Easy
1/5