C4
Viessmann Mixing Valve Control Fault

Thermostat shows C4 and cannot control the mixing valve for a mixed heating circuit; flow temperature is incorrect.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty Viessmann mixing valve actuator, Incorrect wiring of open/close signals, Stuck or seized mixing valve, Misconfigured actuator travel time or type

How to Fix / Troubleshooting

Safety first: Turn off power to the heating controller before working on the mixing valve wiring. Valve and pipes may be hot.

  • Check actuator wiring: Verify that the actuator’s open and close wires are connected to the correct outputs on the controller and that neutral/ground are properly connected if required.
  • Observe valve movement: With power restored and a heat demand present, watch or feel the actuator to see if it moves when the controller calls for temperature changes.
  • Manually move valve (if possible): Some actuators have a manual override. Gently move the valve to ensure it is not seized.
  • Verify configuration: In installer settings, ensure the correct actuator type and travel time are set so the controller can position it accurately.
  • Replace actuator or valve: If the actuator does not respond or the valve is seized, a technician should replace the mixing valve actuator or the valve body.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Viessmann mixing valve actuator