C5
Viessmann DHW Circulation Pump Control Fault

Thermostat displays C5 and indicates that the domestic hot water circulation pump control is faulty.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed DHW circulation pump, Loose wiring to pump output, Overloaded controller output, Incorrect pump schedule or mode configuration

How to Fix / Troubleshooting

Safety first: Turn off power to the boiler and pump circuits. Hot water pipes may be very hot.

  • Check pump schedule: In the thermostat or boiler menu, verify that the DHW circulation schedule is correctly set and not disabled.
  • Inspect pump wiring: Ensure the DHW circulation pump is wired to the correct output terminals and that connections are tight.
  • Listen for pump operation: During a scheduled run, listen or feel for pump vibration. If silent, the pump or output may be faulty.
  • Test pump directly (technician): A professional can test the pump by powering it directly to confirm if it runs.
  • Replace pump or repair output: If the pump is defective, replace it with a compatible Viessmann‑approved model. If the controller output is damaged, the control board may need replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

DHW circulation pump
Check Price on Amazon