Comm Err
Worcester Bosch Digital communication failure between smart thermostat and boiler interface

Thermostat or boiler display shows 'Comm Err' or communication error; setpoint changes on thermostat do not reach boiler.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty EMS/Bosch BUS wiring, Reversed polarity on BUS terminals, Loose plug on boiler control board, Failed boiler interface module

How to Fix / Troubleshooting

Safety first: Isolate mains power to the boiler at the fused spur before touching any wiring. Do not remove sealed combustion covers; only access the external wiring centre or interface terminals.

  • Check BUS wiring: Locate the Worcester Bosch BUS/EMS terminals on the boiler or wiring centre and on the thermostat interface. Ensure the two‑core cable is firmly connected and not damaged.
  • Polarity: Some Worcester Bosch BUS connections are polarity sensitive. Verify that the same conductor goes to the same terminal at both ends (e.g. BUS+ to BUS+, BUS− to BUS−).
  • Inspect for damage: Look for crushed, cut, or water‑damaged cable between thermostat and boiler.
  • Power cycle: After checking wiring, restore power and allow the boiler and thermostat to reboot. Many communication errors clear after a clean restart.
  • If error persists: The boiler interface PCB or thermostat interface module may be faulty. A Gas Safe or qualified heating engineer should test and replace these components.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Worcester Bosch EMS/BUS Interface Module
Check Price on Amazon