Possible Causes
Too tight temperature hysteresis, Incorrect boiler modulation settings, Oversized boiler, Minimum run‑time not configured
How to Fix / Troubleshooting
Safety first: Boiler parameter changes should be made by a competent person following the manual.
- Adjust hysteresis: In thermostat installer settings, increase the temperature differential (e.g. from 0.2°C to 0.5°C) to reduce cycling.
- Minimum on/off times: Set appropriate minimum run and off times if available.
- Boiler settings: Ask a heating engineer to check boiler modulation and pump overrun settings to better match the property.