E1
Wyze
Rc/Rh Power Input Fault
Thermostat reports E1 and will not control heating or cooling after installation or wiring change.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
No 24V power from HVAC transformer, Rc/Rh wire not connected or loose at Wyze base, Blown low-voltage fuse on furnace control board, Miswired Rc/Rh jumper configuration
How to Fix / Troubleshooting
Safety first: Turn off power to the furnace/air handler and outdoor unit at the breaker before touching any thermostat or furnace wiring.
- Verify system power: Ensure the furnace/air handler breaker is ON and the service switch near the unit is ON. If the HVAC system has a low-voltage blade fuse on the control board, visually inspect it for a blown element.
- Check Rc/Rh wiring at Wyze base: Remove the Wyze thermostat display from the wall plate. Confirm the R (or Rc/Rh) wire is fully inserted into the R terminal and the terminal button is fully depressed, with 3/8" of bare copper making contact.
- Confirm R wire at furnace board: At the furnace/air handler control board, verify the same colored wire is firmly attached to the R terminal. Tighten the screw if loose.
- Measure voltage (advanced): With power restored and using a multimeter set to AC volts, measure between R and C at the furnace board. You should see ~24VAC. If not, the transformer or fuse may be faulty and a technician should be called.
- Check Rc/Rh jumper setting: Wyze thermostats typically auto-handle Rc/Rh internally. Ensure you have not manually split R into Rc and Rh unless your system truly has separate heating and cooling transformers.
- Power cycle: After correcting wiring, restore power at the breaker, reattach the thermostat display, and wait 3–5 minutes to see if the E1 code clears.