E60
Wyze
Equipment Detection / Communication Fault
Thermostat shows E60 and cannot detect the furnace or air handler; no response to heat or cool commands.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
No 24VAC power at furnace control board, Loose R or C wires at Wyze base, Blown low-voltage fuse on control board, Wyze C-Wire Adapter wired incorrectly preventing detection
How to Fix / Troubleshooting
Safety first: Turn off power to the furnace/air handler at the breaker before opening panels or touching wiring.
- Check furnace power: Ensure the furnace service switch is ON and the breaker is not tripped. Reset if necessary.
- Inspect low-voltage fuse: On the furnace control board, locate and inspect the low-voltage fuse. Replace with the same rating if blown.
- Verify R and C at thermostat: Remove the Wyze display and confirm that the R and C wires are fully seated in their terminals on the wall plate.
- Check Wyze C-Wire Adapter: If used, confirm all connections match the Wyze wiring diagram exactly. Miswiring can prevent the thermostat from detecting the equipment.
- Restore power and re-run detection: After correcting issues, restore power and use the Wyze app to re-run equipment detection or setup. E60 should clear once the thermostat senses 24VAC and control circuits.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Furnace Control Board Low-Voltage Fuse
Check Price on Amazon