Wyze Open Heating Control Circuit

Thermostat calls for heat but furnace does not start; no error code on thermostat or furnace.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose or disconnected W1 wire at thermostat, Loose W wire at furnace control board, Broken W conductor in thermostat cable, Misconfigured system type in Wyze app

How to Fix / Troubleshooting

Safety first: Turn off furnace power at the breaker before touching wiring.

  • Verify thermostat mode: Ensure the Wyze thermostat is set to Heat and the setpoint is above room temperature.
  • Inspect W1 at thermostat: Remove the display and confirm the W1 wire is fully seated in the W1 terminal.
  • Check W at furnace board: At the control board, ensure the same colored wire is attached to the W terminal and the screw is tight.
  • Bypass test (advanced): With power on and thermostat removed, briefly jumper R to W at the furnace control board. If the furnace starts, the issue is in the thermostat or cable. If it does not, the furnace has an internal issue and a technician is needed.
  • Check Wyze configuration: In the app, confirm the system is set as conventional heat (if applicable) and that W1 is recognized.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Thermostat Cable (W1 Conductor)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements