Wyze No Power to Thermostat

Thermostat screen is completely blank and unresponsive; HVAC system does not run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

No 24VAC between R and C at thermostat, Loose R or C wire at Wyze wall plate, Blown low-voltage fuse on furnace control board, Failed Wyze thermostat display

How to Fix / Troubleshooting

Safety first: Turn off power to the furnace/air handler at the breaker before removing the thermostat.

  • Check furnace power and fuse: Verify the furnace breaker and service switch are ON. Open the blower compartment and inspect the low-voltage fuse on the control board; replace if blown.
  • Inspect R and C at thermostat: Remove the Wyze display and confirm the R and C wires are fully inserted and clamped in their terminals. Re-strip and reinsert if necessary.
  • Measure voltage (advanced): With power restored and using a multimeter, measure AC voltage between R and C at the thermostat wall plate. You should see ~24VAC. If present but the screen is still blank, the thermostat display is likely failed.
  • Test with spare thermostat (if available): Temporarily connect a known-good basic thermostat to confirm the HVAC system powers a thermostat correctly.
  • Replace Wyze thermostat: If there is proper 24VAC at the wall plate and wiring is secure, replace the Wyze thermostat display assembly.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Wyze Thermostat Display Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements