Wyze
Cooling System or Reversing Valve Misoperation
Thermostat shows it is cooling, but warm air blows from vents or house does not cool.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Heat pump reversing valve O/B setting reversed, Outdoor condenser not running due to contactor or capacitor failure, Low refrigerant charge (equipment-side), Y1 circuit miswired to heat instead of cool
How to Fix / Troubleshooting
Safety first: Turn off power to the outdoor unit at the disconnect before opening any panels. Refrigerant work must be done by a licensed technician.
- Check O/B configuration: For heat pumps, verify in the Wyze app whether the reversing valve should energize in heat or cool and set it according to the manufacturer’s specification.
- Verify outdoor unit operation: When cooling is called, check if the outdoor fan and compressor are running. If not, the issue is in the outdoor unit (contactor, capacitor, high-pressure switch) and requires a technician.
- Confirm Y1 wiring: Ensure the Y1 wire from the thermostat goes to the Y terminal on the furnace/air handler and then to the outdoor unit contactor.
- Check air filter and airflow: A severely clogged filter can reduce cooling effectiveness; replace if dirty.
Advertisements
Repair Difficulty
Professional Required