E03
A-iPower
No Fuel / Fuel Supply Fault
A-iPower standby generator cranks but does not start and the controller shows E03 after several attempts.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Empty fuel tank or closed fuel supply valve, Clogged fuel filter, Air in fuel line, Faulty electric fuel pump
How to Fix / Troubleshooting
Safety first: Turn OFF the generator, disconnect the battery, and keep all ignition sources away from fuel. Work in a well-ventilated area.
- Verify fuel supply: Check the fuel gauge and confirm there is adequate gasoline, diesel, or LP/NG supply as specified for your A-iPower model. Ensure any manual shutoff valves on the fuel line are fully open.
- Inspect fuel lines: Look for kinks, cracks, or wet spots indicating leaks. Replace damaged hoses immediately.
- Replace or clean fuel filter: Locate the in-line fuel filter or cartridge filter. Close the fuel valve, remove the filter, and install a new OEM-spec A-iPower fuel filter. Ensure arrow direction matches fuel flow.
- Prime the system (if equipped): Use the manual primer bulb or priming function on the controller to purge air from the fuel line until fuel flows steadily.
- Check electric fuel pump operation: During a start attempt, listen for the fuel pump humming. If silent, check the fuel pump fuse and relay in the control panel. Replace blown fuses only with the same rating.
- If E03 persists: The fuel pump, fuel solenoid, or carburetor/injector may be faulty. Professional diagnosis is recommended to avoid fuel system damage.