E08
A-iPower Battery Voltage Low

A-iPower standby generator controller shows E08 and prevents start or shuts down shortly after start.

Advertisements

Possible Causes

Discharged starting battery, Failed battery charger module, Loose or corroded battery terminals, Parasitic drain from control system

How to Fix / Troubleshooting

Safety first: Turn OFF the generator and disable auto-start. Wear eye protection when working around batteries.

  • Inspect battery terminals: Check for corrosion (white/green buildup) on the battery posts and cable clamps. Clean with a baking soda and water solution, rinse, dry, and tighten connections securely.
  • Measure battery voltage: With a multimeter, measure across the battery terminals. A healthy 12 V battery should read around 12.6 V at rest. If below 12.0 V, charge the battery with an appropriate charger.
  • Check built-in charger: Confirm that the A-iPower battery charger/maintainer is receiving AC power (check its fuse or breaker). Measure battery voltage with AC power applied; it should rise to around 13.4–13.8 V.
  • Look for drains: Ensure no aftermarket accessories are connected directly to the battery. If the battery repeatedly discharges, a parasitic draw or failing battery is likely.
  • Replace battery if needed: Install a new battery that meets the cold cranking amps (CCA) rating specified by A-iPower for your standby model.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Starting Battery
Check Price on Amazon

We may earn a commission from links on this page.