E09
A-iPower Battery Voltage High / Charger Fault

Controller displays E09 and the generator will not crank when a start is requested.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed battery charger overcharging, Incorrect external charger connected, Faulty voltage sensing in controller

How to Fix / Troubleshooting

Safety first: Turn OFF the generator, disconnect AC supply to the charger, and wear eye protection. Overcharged batteries can vent gas and acid.

  • Measure battery voltage: With a multimeter, check the battery. If it reads above ~14.8 V at rest, disconnect the charger immediately.
  • Inspect charger module: Locate the A-iPower battery charger in the control compartment. Check for burnt smell, discoloration, or melted wiring. Ensure its AC input is correctly wired and fused.
  • Remove external chargers: If an external automotive charger or maintainer is connected, disconnect it. Use only the charger specified by A-iPower.
  • Reset system: After disconnecting the charger and allowing the battery to rest, reconnect the battery and clear the code if possible. If voltage returns to normal, replace the faulty charger module.
  • If E09 persists with normal battery voltage: The controller's voltage sensing circuit may be defective and should be evaluated by a service technician.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Battery Charger Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements