E20
A-iPower
Maintenance Interval Exceeded / Service Required
Controller displays E20 and the generator will not start; often accompanied by a service reminder.
Advertisements
Possible Causes
Engine oil change interval exceeded, Air filter service overdue, Controller maintenance timer not reset after service
How to Fix / Troubleshooting
Safety first: Turn OFF the generator and disconnect the battery before performing maintenance.
- Perform scheduled maintenance: Change engine oil and oil filter, replace or clean the air filter, inspect and replace spark plugs (for gasoline/NG/LP models), and check fuel filter as per the A-iPower maintenance schedule.
- Inspect belts and hoses: On liquid-cooled models, check coolant hoses and drive belts for wear or cracking.
- Reset maintenance timer: Follow the A-iPower controller manual to reset the service interval (often via a menu option like "Service Reset" or holding a specific button sequence).
- Record service: Log the date and run hours for future reference.