A-iPower No AC Output Without Fault Code

Generator runs but produces no AC power; controller shows normal run status with no error code.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Tripped generator main breaker, Loose output wiring, Failed AVR, Open stator winding

How to Fix / Troubleshooting

Safety first: Open the transfer switch or main breaker to isolate the generator from the building. Use a meter to confirm no live voltage before touching conductors.

  • Check main breaker: Locate the generator's main circuit breaker and ensure it is in the ON position. Reset if tripped.
  • Inspect output lugs: With the generator off, tighten all output terminal screws and inspect for burnt insulation.
  • Test voltage at generator: With proper PPE, start the generator and measure voltage directly at the generator terminals. If zero, suspect AVR or alternator issues.
  • If no output at terminals: AVR or stator repair is required; contact an A-iPower service center.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Generator Stator
Check Price on Amazon

We may earn a commission from links on this page.