E20
All Power America Sensor Power Supply Failure

Generator display shows E20 and the unit will not start; controller indicates a sensor supply or 5V reference fault.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted sensor (oil, temp, speed), Short in sensor wiring harness, Failed 5V regulator on control board, Moisture causing shorts on PCB

How to Fix / Troubleshooting

Safety first: Turn OFF the generator, disconnect the battery, and avoid static discharge when handling electronics.

  • Visual inspection: Open the control panel and inspect the harness for melted insulation or pinched wires, especially near the engine where heat is high.
  • Unplug sensors one by one: Disconnect oil pressure, temperature, and speed sensors from the harness. Reconnect the battery and see if E20 clears. If the code clears when a specific sensor is unplugged, that sensor or its wiring is shorted and should be replaced.
  • Check 5V reference: With sensors unplugged, measure the 5V reference output from the controller. If absent, the control board's regulator is likely damaged and the board must be replaced.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Generator Control Board
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements