E018
Atlas Copco Air Intake Restriction Alarm

Atlas Copco controller displays E018 Air Filter Restriction / Intake Pressure High

Advertisements

Possible Causes

Clogged air filter element, Collapsed intake hose, Blocked intake grille, Faulty air restriction switch

How to Fix / Troubleshooting

Safety first: Stop the generator and ensure the engine cannot start automatically before opening the air filter housing.

  • Inspect air filter: Open the air filter housing and remove the primary element. If heavily soiled or damaged, replace with a genuine or equivalent filter specified by Atlas Copco.
  • Check intake path: Ensure the intake ducting and rain hood are free of debris, snow, or nesting material.
  • Examine hoses: Look for soft or collapsed intake hoses that may restrict airflow under suction. Replace if deformed.
  • Test restriction switch: If the filter is clean but the alarm persists, test the air restriction switch or sensor with a multimeter and replace if faulty.

After replacement, reset the E018 alarm and run the generator to confirm normal operation.