Controller shows E019 Fuel Water Level High / Water in Fuel
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Possible Causes
How to Fix / Troubleshooting
Safety first: Diesel and water mixtures can be hazardous. Use appropriate containers and dispose of contaminated fuel according to local regulations.
- Drain water separator: Locate the fuel pre‑filter/water separator. Open the drain valve and collect water/fuel until clear diesel flows. Close securely.
- Inspect main tank: Check for signs of water in the main tank (condensation, rust). If significant water is present, the tank may need to be pumped out and cleaned.
- Check sensor: Many separators have an integrated water sensor. Inspect wiring and clean the sensor probe. Replace if the alarm persists with no water present.
- Prevent recurrence: Ensure tank vents are properly capped and that fuel deliveries are from reputable suppliers.
After clearing water and resetting the E019 alarm, run the generator and monitor for reoccurrence.