Atlas Copco
Incomplete Combustion / Possible Coolant Ingress
Excessive white smoke from exhaust on startup that continues after warm‑up
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Low compression, Faulty injectors, Coolant leak into cylinders, Incorrect fuel grade
How to Fix / Troubleshooting
Safety first: Avoid prolonged operation if coolant loss is suspected; engine damage can result.
- Check coolant level: Monitor coolant before and after running. Unexplained loss with white smoke suggests internal leak.
- Verify fuel: Ensure correct diesel grade and no contamination with water.
- Observe warm‑up: Some white smoke at cold start is normal, but it should diminish as the engine warms. If not, schedule injector testing.
- Compression/leak‑down test: Have a technician perform tests to identify internal engine issues.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Fuel Injector Set
Check Price on Amazon
We may earn a commission from links on this page.