Champion
Complete No-Crank Condition
Generator will not start at all, no crank, no click from starter
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Battery completely dead, battery disconnect switch off, failed start/stop switch on controller, open starter relay coil
How to Fix / Troubleshooting
Safety first: Ensure the generator is in OFF mode and the AC breaker is open before working on the battery or starter circuit.
- Verify controller display: If the controller screen is blank, check battery voltage and the battery disconnect switch. Charge or replace the battery as needed.
- Check fuses: Inspect the main DC fuse near the battery and any control fuses in the panel. Replace blown fuses with the correct rating.
- Test start command: Press the MANUAL start button and listen for any relay clicks. No sound may indicate a failed start switch or relay.
- Inspect starter relay: Locate the starter relay in the control compartment. Check for loose connections or heat damage. Replace the relay if it does not energize when a start is commanded.
If the unit still will not crank after these checks, further diagnosis of the controller and wiring harness is required.
Advertisements
Repair Difficulty
Medium
3/5