Champion Moisture Intrusion / Water Leak

Water or moisture is found inside the generator enclosure, on the controller, or on wiring

Advertisements

Possible Causes

Damaged enclosure seals, missing grommets, improper roof or gutter drainage above unit, open conduit entries

How to Fix / Troubleshooting

Safety first: Turn controller to OFF, open the AC breaker, and disconnect the battery before drying any moisture near electrical components.

  • Dry interior: Use clean towels and gentle airflow to dry water from the controller, wiring, and base. Do not use high heat or open flames.
  • Inspect seals and gaskets: Check the enclosure door gaskets, roof seams, and panel joints for cracks or gaps. Replace damaged gaskets.
  • Seal conduit entries: Ensure all conduit penetrations are sealed with appropriate fittings and caulk to prevent water entry.
  • Correct drainage issues: Redirect downspouts or roof runoff away from the generator pad.

Persistent moisture can corrode electrical components; address the source promptly.