Fault Code 415
Cummins
Engine Overspeed Shutdown
Generator shuts down; controller shows Fault Code 415 – Overspeed
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Faulty engine speed sensor, Sticking fuel control actuator, Incorrect governor calibration, Controller speed sensing wiring fault
How to Fix / Troubleshooting
Safety first: Overspeed can cause catastrophic mechanical failure. Do not repeatedly restart until the cause is identified. Disable automatic start.
- Check speed sensor: Locate the Cummins engine speed (magnetic pickup) sensor near the flywheel or crankshaft. Inspect for metal debris on the tip and clean gently. Check the connector and harness for damage.
- Inspect fuel actuator: On electronic engines, ensure the fuel control actuator or throttle body linkage moves freely and is not sticking. Do not force components; binding may require replacement.
- Controller settings: Verify that no unauthorized changes have been made to rated speed or frequency settings in the Cummins controller. Only qualified personnel should adjust governor parameters.
- Reset and test: After basic checks, clear the fault and perform a controlled start while monitoring engine speed and frequency. If overspeed recurs, stop immediately and contact a Cummins service provider.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Engine Speed Sensor
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements