DuroMax
Failure to Transfer Load
Generator starts automatically during outages but does not transfer load
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck ATS contactor, ATS control board fault, Incorrect interlock wiring, Mechanical obstruction in transfer mechanism
How to Fix / Troubleshooting
Safety first: Isolate both utility and generator sources by opening their main breakers. Only qualified persons should service the ATS.
- Observe ATS operation: During a test, watch the ATS contactor. If it hums but does not move, the mechanism may be jammed.
- Manual operation: If the ATS allows manual transfer, attempt to move it. Binding or stiffness indicates mechanical issues.
- Inspect interlocks: Ensure no foreign objects or misaligned covers are blocking the contactor movement.
- Replace contactor or board: A failed contactor coil or control board will need replacement with DuroMax‑approved parts.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Automatic Transfer Switch Contactor
Check Price on Amazon