E19
DuroStar Exhaust System Restriction / Backpressure Fault

Controller shows E19 and the generator shuts down; exhaust may smell of unburned fuel.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Collapsed or blocked muffler, Animal nest or debris in exhaust outlet, Crushed exhaust pipe, Internal muffler failure

How to Fix / Troubleshooting

Safety first: Turn OFF the generator, disconnect the battery, and allow the exhaust system to cool completely before touching it.

  • Inspect exhaust outlet: Check the muffler outlet and any extension piping for obstructions such as nests, mud, or ice. Remove any blockage.
  • Check exhaust piping: Follow the exhaust pipe from the engine to the outlet. Look for crushed sections, kinks, or severe rust. Replace damaged sections.
  • Listen for restriction: When briefly running the engine, listen for hissing or whistling that suggests internal muffler collapse. If present, shut down and replace the muffler.
  • Verify mounting: Ensure the muffler and exhaust brackets are secure and not causing stress that could collapse the pipe.
  • After repair: Clear E19 and run the generator under load while monitoring exhaust flow and engine performance.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Muffler Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements