DuroStar
Weak or Dead Starting Battery
Generator cranks slowly or not at all; no error code displayed on basic control panels.
Advertisements
Possible Causes
Aged battery, Parasitic drain from controller, Faulty battery charger, Loose battery terminals
How to Fix / Troubleshooting
Safety first: Turn the generator OFF and disconnect AC loads. Wear eye protection when handling the battery.
- Inspect terminals: Clean and tighten battery terminals as described earlier.
- Load test battery: Use a battery load tester or have an auto parts store test the battery. Replace if it fails.
- Check charger output: With utility power present, verify that the DuroStar charger maintains 13.2–13.6V at the battery. Replace the charger module if not.
- Prevent future drain: If the generator sits unused for long periods, consider a maintenance charger or ensure the onboard charger is powered continuously.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Starting Battery
Check Price on Amazon
We may earn a commission from links on this page.