DuroStar Weak or Dead Starting Battery

Generator cranks slowly or not at all; no error code displayed on basic control panels.

Advertisements

Possible Causes

Aged battery, Parasitic drain from controller, Faulty battery charger, Loose battery terminals

How to Fix / Troubleshooting

Safety first: Turn the generator OFF and disconnect AC loads. Wear eye protection when handling the battery.

  • Inspect terminals: Clean and tighten battery terminals as described earlier.
  • Load test battery: Use a battery load tester or have an auto parts store test the battery. Replace if it fails.
  • Check charger output: With utility power present, verify that the DuroStar charger maintains 13.2–13.6V at the battery. Replace the charger module if not.
  • Prevent future drain: If the generator sits unused for long periods, consider a maintenance charger or ensure the onboard charger is powered continuously.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Starting Battery
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements