FG Wilson Governor Hunting / Speed Instability

Generator frequency is unstable or fluctuates under steady load

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Incorrect governor gain settings, Worn mechanical governor linkage, Air in fuel system, Variable load with poor power factor

How to Fix / Troubleshooting

Safety first: Monitor frequency and voltage with appropriate instruments. Avoid connecting sensitive equipment until stability is restored.

  • Check fuel system: Ensure filters are clean and there is no air in the fuel lines.
  • Inspect governor linkage: On mechanical systems, lubricate and free any stiff joints. Ensure return springs are intact.
  • Stabilize load: If large motor loads are cycling on and off, consider staggering their start times or using soft starters.
  • Adjust governor (advanced): Electronic governor parameters (gain, stability) should be adjusted only by trained personnel using the correct tools and manuals.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Engine Governor/Actuator
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements