Firman Nuisance Auto-Start / False Utility Loss Detection

Generator frequently starts and stops for short periods even when utility power is stable.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose utility sense wiring, Voltage fluctuations on utility line, Misconfigured start/stop thresholds, Faulty controller sensing circuit

How to Fix / Troubleshooting

Safety first: Turn OFF the generator and lock out the ATS if possible. Only qualified persons should work on live utility circuits.

  • Inspect sense wiring: Check all low-voltage sense wires between the ATS and Firman controller for tight connections and correct routing.
  • Monitor utility voltage: Use a recording meter to verify that utility voltage is within acceptable limits. If it is unstable, contact the utility provider.
  • Review controller settings: In the controller menu, verify start/stop voltage and time delays are set per Firman recommendations to avoid reacting to brief sags.
  • Check for electrical noise: Ensure sense wires are not run parallel to high-current conductors without shielding, which can induce false readings.

If nuisance starts continue, the controller's sensing circuit may need evaluation or replacement.

Advertisements

Repair Difficulty

Hard 4/5

Required Part

Generator Control Board