Firman
Load Starting Surge / Breaker Trip
Generator runs but trips its main breaker or house breakers when large loads start (e.g., air conditioner).
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Load exceeds generator surge capacity, Weak main breaker, Motor loads starting simultaneously, Loose connections causing heat and nuisance trips
How to Fix / Troubleshooting
Safety first: Turn OFF the generator and ATS before working on breakers or wiring.
- Stagger load starts: Configure high-surge loads (HVAC, pumps) to start at different times or use load-shedding controls if available.
- Check breaker rating: Confirm the Firman generator main breaker rating matches the generator's kW rating and has not been downgraded.
- Inspect connections: Tighten all lugs at the generator main breaker and ATS. Overheated connections can weaken breakers.
- Replace weak breaker: If the main breaker trips at currents below its rating, replace it with an OEM-equivalent breaker.
If your standby generator is undersized for your home's starting loads, consult an electrician about load management or upgrading capacity.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Generator Main Breaker
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements