Possible Causes

Load exceeds generator surge capacity, Weak main breaker, Motor loads starting simultaneously, Loose connections causing heat and nuisance trips

How to Fix / Troubleshooting

Safety first: Turn OFF the generator and ATS before working on breakers or wiring.

  • Stagger load starts: Configure high-surge loads (HVAC, pumps) to start at different times or use load-shedding controls if available.
  • Check breaker rating: Confirm the Firman generator main breaker rating matches the generator's kW rating and has not been downgraded.
  • Inspect connections: Tighten all lugs at the generator main breaker and ATS. Overheated connections can weaken breakers.
  • Replace weak breaker: If the main breaker trips at currents below its rating, replace it with an OEM-equivalent breaker.

If your standby generator is undersized for your home's starting loads, consult an electrician about load management or upgrading capacity.