Firman
Engine Hunting / Unstable Speed
Generator runs roughly, surging up and down in RPM with fluctuating lights in the house.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty carburetor or injectors, Misadjusted governor, Vacuum leak at intake manifold, Restricted fuel supply
How to Fix / Troubleshooting
Safety first: Turn OFF the generator and disconnect battery negative before mechanical adjustments.
- Inspect fuel system: Replace the fuel filter and ensure fuel lines are clear and not kinked.
- Clean carburetor/injectors: Use appropriate cleaner or have injectors professionally serviced.
- Check for vacuum leaks: Spray a small amount of carb cleaner around the intake manifold gasket while the engine is running; a change in RPM indicates a leak that needs gasket replacement.
- Adjust governor: Follow Firman service procedures to set governor linkage and spring tension for stable speed.
Persistent hunting after basic cleaning and checks should be addressed by a technician with proper test equipment.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Governor Linkage Assembly
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements