GE Control Panel Power or Display Failure

Controller display is blank or unreadable

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown low-voltage fuse, Failed display module, Loose ribbon cable, No DC power from battery

How to Fix / Troubleshooting

Safety First: Turn OFF utility and generator breakers. Disconnect the negative battery cable before removing the control panel cover.

  • 1. Check battery voltage: Verify the battery has at least 12.4 V. Recharge or replace if low.
  • 2. Inspect DC fuse: Locate the control circuit fuse near the GE controller. Replace if blown with the same rating.
  • 3. Check display connections: Remove the controller cover and ensure the ribbon cable between the main board and display is fully seated.
  • 4. Look for moisture damage: Inspect the display and board for signs of water intrusion or corrosion. Dry and clean if minor; replace modules if severely damaged.
  • 5. If still blank: The display or entire controller may need replacement with a GE-approved control panel.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Controller Display Module
Check Price on Amazon

We may earn a commission from links on this page.