GE Unstable Governor Operation

Generator engine hunts or surges up and down in speed

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Dirty carburetor or fuel mixer, Sticking governor linkage, Incorrect fuel pressure, Weak governor spring

How to Fix / Troubleshooting

Safety First: Keep hands and tools away from moving linkages while the engine is running. Turn OFF the unit before adjusting or cleaning components.

  • 1. Inspect and clean linkage: With engine off, move the governor and throttle linkages through their range. Clean and lightly lubricate pivot points.
  • 2. Check air and fuel filters: Replace clogged air and fuel filters to ensure proper mixture.
  • 3. Verify fuel pressure: Have a gas technician confirm that inlet pressure is within GE specifications for LP or NG.
  • 4. Clean carburetor/mixer: On carbureted units, clean jets and passages. On mixer-type systems, ensure the mixer diaphragm is intact and not sticking.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Governor Linkage
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements