ESTOP ACTIVE
Guardian Remote Emergency Stop or Shutdown Input Active

Display shows ESTOP ACTIVE or REMOTE STOP; generator remains locked out.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Remote E-stop station engaged, Faulty remote wiring, Shorted remote stop input on control board, Misconfigured external monitoring system

How to Fix / Troubleshooting

Safety first: Confirm there is no real emergency condition before clearing any remote stop.

  • Locate remote E-stop: Identify any remote emergency stop stations connected to the Guardian generator. Reset them according to their design.
  • Inspect remote wiring: Check the low-voltage wiring from remote devices to the generator controller for shorts to ground or open circuits.
  • Disconnect test: Temporarily disconnect the remote stop wiring at the controller terminal strip. If the alarm clears, the issue is in the remote circuit.
  • Controller input check: If the alarm remains with remote wiring removed, the control board input may be shorted and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Remote Stop Input Circuit (Control Board)
Check Price on Amazon

We may earn a commission from links on this page.