INTAKE AIR TEMP HIGH
Guardian High Intake Air Temperature Alarm

Controller shows INTAKE AIR TEMP HIGH; generator may derate or shut down in hot weather.

Advertisements

Possible Causes

Blocked enclosure ventilation, Operation in direct sun with inadequate clearance, Failed intake temperature sensor, High ambient temperature beyond rating

How to Fix / Troubleshooting

Safety first: Place the controller in OFF and open the main breaker. Allow the unit to cool.

  • Check ventilation: Ensure all Guardian enclosure louvers are clear and that minimum clearances from walls and vegetation are maintained.
  • Shade and airflow: If installed in direct sun, consider adding shading that does not block airflow.
  • Inspect sensor: Locate the intake air temperature sensor and verify the connector is secure. Replace the sensor if physically damaged.
  • Reset and test: Clear the alarm and run the unit during cooler hours to confirm operation. Persistent alarms in normal ambient conditions require technician evaluation.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Intake Air Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements