LOW FUEL PRESSURE
Guardian Insufficient Fuel Supply Pressure

Generator starts to crank but stalls or runs rough, then shuts down with LOW FUEL PRESSURE or FUEL SUPPLY error.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

LP tank nearly empty or NG supply undersized, Blocked fuel filter, Maladjusted or failed Guardian fuel regulator, Frozen or water-contaminated fuel line

How to Fix / Troubleshooting

Safety first: Turn the controller to OFF, open the main breaker, and close the gas shutoff valve. Work only in a well-ventilated outdoor area. Do not smoke or create sparks near fuel.

  • Check fuel source: Verify LP tank level is adequate and that the main tank valve is fully open. For NG, confirm gas service is active and sized per Guardian installation requirements.
  • Inspect fuel piping: Look for crushed, kinked, or sagging flexible fuel lines. Correct any mechanical damage and ensure proper support.
  • Replace fuel filter: If equipped, replace the in-line fuel filter with a Guardian-approved part to remove restrictions.
  • Check regulator vent: Ensure the regulator vent is not blocked by insects, dirt, or ice. Clear obstructions carefully.
  • Test run: Reopen the gas valve, leak-test connections with a soap solution, then reset the controller and perform a manual start. If LOW FUEL PRESSURE persists, the regulator or gas supply sizing must be evaluated by a licensed gas technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Fuel Regulator