E11
Himoinsa No Engine Speed Signal / RPM Sensor Failure

Generator controller indicates E11 and the engine shuts down after a few seconds of running.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective magnetic pickup sensor, Incorrect sensor gap to flywheel, Broken speed sensor cable, Faulty controller speed input

How to Fix / Troubleshooting

Safety: Turn OFF generator, isolate battery, and wait for all rotating parts to stop.

  • Locate speed sensor: Find the magnetic pickup on the flywheel housing or timing gear cover. Refer to the Himoinsa engine layout diagram.
  • Inspect sensor and gap: Remove the sensor and check for metal filings on the tip. Clean it and reinstall with the correct air gap (typically 0.5–1.0 mm; confirm in engine manual).
  • Check cable continuity: Use a multimeter to test continuity from the sensor connector to the controller terminals. Repair or replace damaged cables.
  • Measure sensor output: With the sensor installed, crank the engine and measure AC voltage at the sensor leads; a small AC voltage should be present. If not, replace the sensor.
  • Controller input test: If a known-good sensor and wiring are present but E11 persists, the controller speed input may be defective and require replacement by a qualified technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Magnetic Pickup Speed Sensor
Check Price on Amazon