E09
Honda
Overcurrent / Overload Trip
Generator shuts down and displays E09 when large loads start (e.g., air conditioner)
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Total load exceeds generator kW rating, Short circuit or ground fault on load side, Sticking or weak main circuit breaker, Incorrect wiring at transfer switch causing phase imbalance
How to Fix / Troubleshooting
Safety first: Open the generator main breaker and the building's transfer switch or main disconnect before inspection. Turn OFF the generator and disable auto-start.
- Reduce load: Identify and temporarily turn off high-demand loads (HVAC, electric ovens, water heaters). Attempt a manual run with only essential circuits. If E09 does not recur, your system is overloaded and needs load management or a larger generator.
- Inspect main breaker: Check the generator's main breaker for signs of overheating, burning, or mechanical damage. Cycle it OFF and ON several times. A breaker that feels loose or fails to latch may need replacement.
- Check for wiring faults: Have a qualified electrician inspect the transfer switch and load center for shorts, loose connections, or miswired circuits. Overcurrent can be caused by a shorted branch circuit.
- Measure current draw (electrician): Using a clamp meter, measure current on each phase during operation to ensure it is within the generator's rated output and reasonably balanced.
- Do not bypass protection: Never bypass or oversize the main breaker to stop E09; this can cause fire or equipment damage.