Honda
Loss of Excitation / No Output
Generator runs but produces no AC power at the output terminals
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed AVR, Open field winding, Tripped or failed main breaker, Broken rotor or stator connections
How to Fix / Troubleshooting
Safety first: Ensure the generator is shut down, main breaker open, and battery negative disconnected. High voltages may be present when running; only qualified persons should test live circuits.
- Check main breaker: Confirm that the generator's main breaker is not tripped. Reset if necessary. If it trips immediately on start, investigate for shorts.
- Inspect alternator wiring: Remove the alternator terminal cover and check for broken or disconnected stator leads.
- Test AVR: If safe and qualified, measure field voltage from the AVR to the rotor while cranking or running. No field voltage suggests a failed AVR or open field circuit.
- Field flashing (advanced): Some alternators may require field flashing if residual magnetism is lost. This should only be done by a technician following Honda's procedure.
- Professional repair: Open windings or rotor faults require alternator disassembly and are not DIY-friendly.